©εοΔΰΦ | vOϊ{κΕ |
EEE 27ρ€εοvO pκΕ EEE
27th Annual Technical Meeting on Air Cleaning and Contamination Control Program
No. | Title | Date | Time |
A01 | Cancelled | 4/14 | 10:00 |
A02 | Airflow characteristics and contaminant induction by the movements of a large vehicle in cleanroom (Part 1) Experiments in a large-size model cleanroom | 4/14 | 10:20 |
A03 | Airflow characteristics and induced contaminations by the motion of large vehicles in cleanrooms (Part 2) Airflow visualization and computer simulation | 4/14 | 10:40 |
A04 | A study on the fragmentation process of condensed organic compounds | 4/14 | 11:00 |
A05 | Research on Environment Control Technologies of New Clean Room Part1. Evaluation of Cleanliness in Local Area around Mini-environment Devices | 4/14 | 11:20 |
A06 | Simulation Method of Air Pressure for Ventilation System in Biological Clean Room | 4/14 | 14:00 |
A07 | Study on the Door Passage Air Current for Maintaining Clean Environment | 4/14 | 14:20 |
A08 | Development and Cleanliness of The Local Air Cleaner (Open Clean Bench) by The Opposite Uniform Flow | 4/14 | 14:40 |
A09 | Transient Heat and Moisture Analysis inside the Wall of the Wooden Dwellings with the Membrane to Change its Moisture Resistance Factor with the Ambient Humidity | 4/14 | 15:00 |
A10 | Study of dew condensation on interior materials induced by the water spray humidification (Part 2) The consideration on the distance of vapor absorption | 4/14 | 15:20 |
A11 | Study on nanoparticle generation caused by gases in cleanroom | 4/14 | 15:40 |
A12 | Cancelled | @ | @ |
A13 | Bayesian Statistics for the Classification of Air Cleanliness for Cleanrooms | 4/14 | 16:00 |
A14 | The removal performance of the outdoor-air-handling unit for the sodium ion of sea-salt particles | 4/14 | 16:20 |
A15 | Basic Research on Gaseous and Particulate Partitioning for SVOC in Indoor Air | 4/15 | 9:40 |
A16 | Characterization of nano-sized particle emission from office machines by ISO-compliant chamber method | 4/15 | 10:00 |
A17 | Relation between the second generation and VOC of ultrafine particle | 4/15 | 10:20 |
A18 | Parallel plate wet denuder coupled ion chromatography for near real-time monitoring of acid gases in clean room environment | 4/15 | 10:40 |
A19 | The importance of the on-site measurement of the acetic acid / formic acid in the semiconductor clean room | 4/15 | 11:00 |
A20 | Selective Detection of Dioctylphthalate by Molecular-sieving Gas Sensor | 4/15 | 11:20 |
A21 | Relationship between outgas emission rate from constitute material and concentration of surrounding ammonia gas | 4/15 | 14:20 |
A22 | Brief evaluation of semiconductor manufacturing environment air contamination using high sensitive solid adsorbent active sampler | 4/15 | 14:40 |
A23 | Enhance Reticle Purging Performance by Nitrogen/Compressed Dry air | 4/15 | 15:00 |
A24 | Ensuring Contamination Control in Clean Manufacturing Environments - Airborne Molecular Contamination Monitoring | 4/15 | 15:20 |
A25 | Application of JIS-11@Kanto Loam powder to collection performance evaluation of general ventilation air filters | 4/15 | 15:40 |
A26 | Fractional Collection Efficiency Evaluation for General Ventilation Air Filters using JIS-11 Test Powder | 4/15 | 16:00 |
A27 | Uncertainty of performance tests in light scattering airborne particle counter | 4/15 | 16:20 |
A28 | Investigation of the Particle Generation Technique for Flat Number-Size Distribution | 4/15 | 16:40 |
B01 | Application of ultrasonic mist to air purification method - Part 1 Mist formation from binary liquid and its size distribution | 4/14 | 10:00 |
B02 | Application of ultrasonic mist to air purification method - Part 2@Degradation of VOC gas on ultrasonic mist including titania particles | 4/14 | 10:20 |
B03 | Development of removal equipment for VOC in exhaust gas by using gas-liquid contact method with PUF (Poly Urethane Foam) | 4/14 | 10:40 |
B04 | Development of removal equipment for VOC exhausted from coating and printing plant by using parallel plate type of diffusion scrubber with porous PTFE membrane unit (vertical type) | 4/14 | 11:00 |
B05 | The Development of the Photo Catalyst Cloth for the Gas Removal | 4/14 | 11:20 |
B06 | A study on the actual status of the microbial contamination in small-scale buildings due to seasonal influence | 4/14 | 14:00 |
B07 | Actual Survey about Indoor Air Contamination by Microbe in Buildings with Geothermal Utilization Pit | 4/14 | 14:20 |
B08 | The comparison of sterilization abilities between formaldehyde and hydrogen peroxide | 4/14 | 14:40 |
B09 | A small hydrogen peroxide sterilizer | 4/14 | 15:00 |
B10 | Development of newly invented MRG (Methanol Radical Gas) sterilization system | 4/14 | 15:20 |
B11 | Basic study of bacteria inactivation by using microplasma | 4/14 | 15:40 |
B12 | About an Anti-fungus Action of the Perfume used for Aromatherapie | 4/14 | 16:00 |
B13 | Performance of air filter with inactivator of influenza virus | 4/14 | 16:20 |
B14 | Cancelled | 4/14 | 16:40 |
B15 | Quality Control of Clean Room Garment by Using IC TAG 2 | 4/15 | 9:40 |
B16 | A study on the deterioration of clean room garment by laundry and actual use | 4/15 | 10:00 |
B17 | Development of Residual HCHO removal systems from the Evaporation Pasteurization of Biological Cleanroom | 4/15 | 10:20 |
B18 | Air Cleaning Performance of Ventilating Air Purification System with Water | 4/15 | 10:40 |
B19 | Removal of harmful chemicals from atmosphere by salmon-milt DNA | 4/15 | 11:00 |
B20 | Basic study on indoor air purification using atmospheric microplasma (U) | 4/15 | 11:20 |
B21 | Study on Ion Transpotation Discharge Device (2) |@Numerical Analysis of Air Ions@| | 4/15 | 14:20 |
B22 | Study on Ion Transportation Discharge Device (3) \ Examination about the ion density decrement characteristic at the time of the ion transportation \ | 4/15 | 14:40 |
B23 | Development of ion conveying type ionization system generating large charged-particles by condensing water vapor onto ion (Part 2) | 4/15 | 15:00 |
B24 | A study on the properties of Air Ions from Contamination sources & their behavior | 4/15 | 15:20 |
B25 | Electrostatic Characteristic of Clean Room Interior Materials in the Low Humidity | 4/15 | 15:40 |
B26 | Electrostatic Discharge Process of Ultra-Low Voltage | 4/15 | 16:00 |
B27 | Measurement of ionic compounds under the electric field in indoor air | 4/15 | 16:20 |
Committee Reports | 4/15 | 16:40 | |
C01 | A Study on the Emission Rates of Chemical Substances on Room Air Cleaners | 4/14 | 10:00 |
C02 | Studies on Performance Evaluation of Room Air Cleaners for Gaseous Contaminants and the Indoor Concentration Prediction Method (Part 6) | 4/14 | 10:20 |
C03 | Studies on Performance Evaluation of Room Air Cleaners for Gaseous Contaminants and the Indoor Concentration Prediction Method (Part 7) | 4/14 | 10:40 |
C04 | Studies on the Indoor Air Pollution in the School Environment (Part 2), Chemical Substance Emission Rates on Educational Equipments | 4/14 | 11:00 |
C05 | Studies on the Indoor Air Chemical Pollution in the School Environmental(Part 3), Emission Rates of Chemical Substances on a Satchel | 4/14 | 11:20 |
C06 | Studies on the Removal Performance of Gaseous Contaminants on Room Fresheners (Part 4), Concentration Pattern of Suspended Particulate Matters with Use of Room Freshener | 4/14 | 14:00 |
C07 | Studies on Tests and Evaluation Methods of Odorant Removal Performance for a Urinal Toilet Unit with Deodorization Devices(Part 5), The Emission Rates of Gaseous Pollutants from Human Wastes | 4/14 | 14:20 |
C08 | Studies on Tests and Evaluation Methods of Odorant Removal Performance for a Urinal Toilet Unit with Deodorization Devices (Part 6), Gaseous Pollutants Removal Performance for the Toilet Unit with Deodorization Devices | 4/14 | 14:40 |
C09 | A Study on the Test and Evaluation Method for Chemical Substance Emissions from Electrical Heaters | 4/14 | 15:00 |
C10 | The measurement result of the amount of TVOC personal exposure | 4/14 | 15:20 |
C11 | Measurement of air pollution gases (NO2,SO2,NH3) by using collection tube coated with TiO2 by diffusion scrubber method | 4/14 | 15:40 |
C12 | Determination Method of the Styrene in Indoor Air | 4/14 | 16:00 |
C13 | Determination method of the formic acid in indoor air | 4/14 | 16:20 |
C14 | Development of simple preparation of trace standard gases by diffusion scrubber method -trace standard gas generation during long period- | 4/14 | 16:40 |
C15 | Examination of air-filter unit utilizing the media effectively | 4/15 | 9:40 |
C16 | Filtration of nanoparticles in the composites of nanofiber and microsized polymer particles | 4/15 | 10:00 |
C17 | Development of controlling technique in electrospinning method for fiber production | 4/15 | 10:20 |
C18 | Development of microslit-nozzle for cleaning the functional films | 4/15 | 10:40 |
C19 | Cleaning Technology for Substrate Using Focused Ultrasound | 4/15 | 11:00 |
C20 | A study on the Analysis of H2O activated structure using NMR (Nuclear Magnetic Resonance) (Part2) | 4/15 | 11:20 |
C21 | A study on the development of New Air Conditioning Systems used Oscillating Heat Pipe | 4/15 | 14:20 |
C22 | Development of Ion Removed Water Supply System serviced makeup water for cooling tower | 4/15 | 14:40 |
C23 | Effect of energy conservation of Vapor Crystal Clean air-conditioning System | 4/15 | 15:00 |
C24 | Research on the eTask and Ambientf Air Cleaning System (Part.5 Reducing Carbon Dioxide Emission) | 4/15 | 15:20 |
C25 | Comparisons on the Newly Proposed Locally Balanced and the Wall-return Turbulent Type Clean Rooms | 4/15 | 15:40 |
C26 | Power Consumption of 300mm DRAM Wafer Fabs in Taiwan | 4/15 | 16:00 |
C27 | Applying Functional Filter for Removal Atmospheric Acid-Odor | 4/15 | 16:20 |
C28 | Ventilation Effectiveness of a Bathroom with Negative-pressure Ventilation Schemes | 4/15 | 16:40 |
E-mailFjaca@jaca-1963.or.jp
Copyright(C)2001 Japan Air Cleaning Association