←大会案内へ プログラム日本語版

・・・ 第28回研究大会プログラム 英語版 ・・・

28th Annual Technical Meeting on Air Cleaning and Contamination Control Program

No. Title Date Time
A01Development of micro-ammonia monitor7/510:00
A02Study on Improvement in Practical Application with a QCM Surface Modification Type Sensor7/510:20
A03Cleaning performance of the nitrogen purge process when a Front Opening Unified Pod (FOUP) is contaminated by Hydrogen Fluoride (HF) and Volatile Organic Compound (VOC)7/510:40
A04Development of removal equipment for VOC exhausted from coating and printing plants by using parallel plate type of diffusion scrubber with Porous PTFE membrane Panel7/511:00
A05Development of reproduction technology for the removal solution which absorbs VOC gases by vacuum evaporation with air flow7/511:20
A06Development of removal equipment for VOC gas exhausted from coating and printing plant by spraying removal solution with PUF (Poly Urethane Foam)7/511:40
A07Study of Simulated Indoor Air Treatment by Atmospheric Microplasma (2) 7/514:00
A08Studies on the Deterioration of Gaseous Contaminants Removal Performance on Room Air Cleaners (Part 5)7/514:20
A09Studies on the Removal Performance of Gaseous Contaminants on Room Fresheners (Part 5)
Proposition of evaluate and test method for room fresheners
7/514:40
A10Fundamental study on removal of volatile organic compounds (VOCs) using (APA: acrylamide polyampholytes)-containing mists atomized by various kinds of atomizer 7/515:00
A11Evaluation of VOC gas degradation efficiency by ozone decomposition catalyst under ozone existence condition 7/515:20
A12Synthesis of visible light-sensitive WO3-Pt photocatalyst and their characterization 7/515:40
A13A study on the development of wearing system used in the clean dry room7/69:20
A14Protective performance of protective clothing against biological hazardous agents7/69:40
A15Evaluation of air flow by measurement of pressure7/610:00
A16Research on Task Air Cleaning System for BCR Operating Room7/610:20
A17Thermal clean chamber for equalizing the temperature of FPD panel with new airflow system7/610:40
A18Removal Performance of Particulate Matter by a Portable Air Cleaner
Part 1 Evaluation Methodology of Removal Performance for Suspended Particulate Matter
7/611:00
A19Removal Performance of Particulate Matter by Portable Air Cleaners
Part 2 Removal Performance for Airborne Ultrafine Particles
7/611:20
A20Preparation of multi-layer nanofibrous air filter by electrospinning and its performance evaluation 7/611:40
A21An experiment and proposal on suitable particle size and suitable parameters for installed filter system leakage test7/613:00
A22Application of Chitosan Nanofibers with branching structure to air filter7/613:20
A23Studies to relate to the total filter which we wash it, and put a reusable pre-filter and a main filter in the same frames corresponding to zero-emission (Continuance studies) 7/613:40
A24Study on the evaluation of metal contamination in the rechargeable battery manufacturing environment 7/614:00
A25Evaluation of non-unidirectional cleanrooms which provides cleanliness recovery performance uniquely 7/614:20
A26Development of air-conditioning system that suppresses energy consumed according to dehumidification load7/614:40
A27Research on the 'Task and Ambient' Air Cleaning System
(Part 7 Ventilation Efficiency of Air Cleaning System)
7/615:00
A28Research on the 'Task and Ambient' Air Cleaning System (Part 8 Temperature Stratification Type Local Air Cleaning System)7/615:20
A29Research on the 'Task and Ambient' Air Cleaning System
(Part 9 Dispersion of Particles Deposited on Floor by Walking)
7/615:40
A30Mass Analysis of Compositions of Ions Generated by Corona Discharge Ionizer and of Relevant Ion-Molecule Reactions7/616:00
A31Experimental Study on Neutralization Effect of Glass Substrate by Ionizer 7/616:20
A32Optimization of charge eliminating performance on low energy X-ray ionizer with shielding structure7/616:40
Committee Report7/617:00
B01Uncertainty of counting efficiency in the light scattering airborne particle counter at lower concentrations area7/510:00
B02Optical Measurement of Particles Diameter and Refractive Index on the Glass Surface by Light-Scattering7/510:20
B03Basic study of distinction between conductive particle and non-conductive particle by means of light scattering7/510:40
B04Time-dependent Change of Particle Size Distribution during Secondary Formation Process of UFPs - Modelling and Computer Simulation -7/511:00
B05Aerosol Formation from VOC in Indoor Air by UV light and Ozone7/511:20
B06Secondary Organic Aerosol Formation in Residential Room Exposed by UV light7/511:40
B07Characterization of ultrafine particle collection for various air filters and their application to laser printers (Part 2)7/514:00
B08Characterization of ultrafine particle collection by different kinds of samplers for evaluating air quality in workplaces for nanomaterial production7/514:20
B09Verification of mechanisms for ultrafine particle generation from laser printers7/514:40
B10Collection of MWCNT by air filter7/515:00
B11A Study on Optimization Inlet/Outlet Layout of HVAC System with thermal effect7/515:20
B12Enhancement in performance of spacial isolation of environmental tobacco smoke at a low interfacial velocity7/515:40
B13Experiments on ventilation performance at driving condition of automobile7/69:20
B14Formation of secondary organic aerosol particles from VOCs emitted from various sorts of housekeeping wares used in the actual residence room7/69:40
B15Study on Indoor Air Pollution by Airborne Particulate Matters7/1010:00
B16Study of abnormal state detection from time variation in atmospheric aerosol number concentration, and its application7/610:20
B17Cancelled7/610:40
B18A Study on Chemical Substance Pollution in the Compartment of the Car7/611:00
B19A Study on Actual Survey of Smoke Separating at restaurants7/611:20
B20Actual Condition Survey of KARAOKE-BOX restaurants7/611:40
B21Evaluation of Take-off of Microbe from Finned Coil for HVAC System, Part17/613:00
B22Evaluation of Take-off of Microbe from Finned Coil for HVAC System, Part27/613:20
B23Study on Microbial Contamination of Ceramics Material Conditioning for Humidification and Deodorization in Geothermal Utilization Pit7/613:40
B24Measurement of microbes in Air Handling Unit for cleanroom which installed evaporative humidification module7/614:00
B25On the actual condition to indoor air distribution in a high airtight residence, and microbe concentration(Part2)7/614:20
B26An experimental consideration of a decontamination method with vaporized hydrogen peroxide7/614:40
B27Examination of the Anti-microbe Measure with the Chlorine-based Chemical
(Part 5) Relationship between Biological Indicator and CT value
7/615:00
B28Study of bacteria sterilization by using atmospheric microplasma7/615:20
B29Examination of air-conditioning system fungous contamination and proposal of assessment guideline (Part 2)7/615:40
B30A study of an evaluation technique of the diffusion of biohazard in the air, by using a surrogate liquid7/616:00
B31Simultaneous analysis of organic acids in atmosphere by capillary zone electrophoresis7/616:20
B32The development of the passive sampler for formaldehyde using 2,4-pentanedione impregnation silica gel scavenger7/616:40
B33The development of the active sampler for formaldehyde using 2,4-pentanedione impregnation silica gel scavenger (2) 7/617:00

E-mail:jaca@jaca-1963.or.jp
Copyright(C)2001 Japan Air Cleaning Association