ฉ‘ๅ‰๏ˆฤ“เ‚ึ ƒvƒƒOƒ‰ƒ€“๚–{Œ๊”ล

EEE ‘ๆ30‰๑Œค‹†‘ๅ‰๏ƒvƒƒOƒ‰ƒ€ ‰pŒ๊”ล EEE

30th Annual Technical Meeting on Air Cleaning and Contamination Control Program

No. Title Date Time
A01Characterization of release of nanomaterial-derived particles and their collection by inertial samplers4/2310:00
A02Evaluation of gas adsorption artifacts in the collection of atmospheric ultrafine particles using inertial filter sampler4/2310:20
A03Extending the size range for calibrating the counting efficiency of the light scattering airborne particle counters toward larger particle sizes4/2310:40
A04Optical measurement method for particles on printed substrate surface by light-scattering4/2311:00
A05Examination of measurement method for environmental Japanese cedar pollen allergen4/2311:20
A06Stochastic detection method of contamination on real-time from time variation in aerosol number concentration4/2311:40
A07Development of a Computational Software for the Annual Energy Consumption of High-Tech Fabs 4/2313:00
A08Experimental study on smart factory energy management system for cleanroom4/2313:20
A09Measurement and Analysis of Heat Dissipation Characteristic of Manufacturing Equipment to Cleanroom 4/2313:40
A10Improving the Dehumidification Performance and Energy Efficiency of Low Dew Point Desiccant Dehumidifier 4/2314:00
A11Study on Preventive Measures against Exposure to Nanomaterials at Workplace 4/2314:20
A12Research on the gTask and Ambienth Air Cleaning System
(Part.12 Reentrainment of deposited particles)
4/2314:40
A13Expected performances and effectiveness of Air Shower4/2315:00
A14Airflow characteristic around door opening with moving objects4/2315:20
A15Pre-particle Filtration and Moisture Control by efficient purging in various inlet and outlet of a 450 mm wafer Front-Opening Unified Pod4/249:40
A16Study on Assessing the Particulate Containment Performance in Facility for High Potent Pharmaceutical Compounds4/2410:00
A17A study of an evaluation technique of the hazardous particulate containment performance in the facilities for highly active medicals (Part 3)4/2410:20
A18Basic study of biological particle detection method utilizing auto fluorescence 4/2410:40
A19Research on the "Task and Ambient" BCR Operating Room 4/2411:00
A20Task Air Cleaning System for Hybrid Operating Room 4/2411:20
A21Verification of the effect of gpush-pullh airflow to reduce the concentration of airborne microbe generated by coughing equipment using BN-spores4/2411:40
A22Sterilization with Ozone in a Clean Room of Pharmaceutical Manufacturing Facility4/2414:50
A23Experimental Results of Bio-decontamination Technology for using Hydrogen Peroxide Vapor 4/2415:10
A24Effect of Additives on Sterilization of Bacteria by Atmospheric Microplasma 4/2415:30
B01On the actual condition to indoor air distribution and microbe concentration in a high airtight residence. (Part 3)4/2310:00
B02Theoretical examination about the mold multiplication characteristic in the building-materials surface4/2310:20
B03Characteristic of the fungus contamination in a heat cool trench 4/2310:40
B04Fundamental examination about the multiplication characteristic of the fungus in a coexistence state4/2311:00
B05Onsite certification of HEPA filter mounted on class II biological safety cabinets: significant insensitivity of tests utilizing particle counters4/2311:20
B06A recent experience with onsite certification of class II biological safety cabinet4/2311:40
B07Investigation of radioactive particles in aerosol at Fukushima Prefecture4/2313:00
B08A study on counter measure technique against environmental pollution caused by radioactive substances (Part 1), Development of recovery-circulation-type decontamination machine4/2313:20
B09Cancelled4/2313:40
B10A study on recovery method of the used activated carbon adapted for air clean device (Part 1)4/2314:00
B11A study on the odor substance on the toilet deodorant devices4/2314:20
B12Influence of removal performance by the particle removal test for portable air cleaner4/2314:40
B13Countermeasure of Formaldehyde in the Hospital4/2315:00
B14High performance filter utilizing nano-fiber non-woven sheets4/2315:20
B15Development of removal technology for IPA (Isoropyl alcohol) in exhaust gas by spraying removal solution4/249:40
B16Development of the regeneration equipment for the waste solvent which absorbs VOC gas by vacuum evaporation with air flow4/2410:00
B17Removal of volatile organic compounds by spraying APA (acrylamide polyampholyte)-containing solution using various sorts of spraying method4/2410:20
B18A study on pollutant removal performance by photocatalyst products4/2410:40
B19Evaluation of VOC decomposition ability by the difference of ozone decomposition catalyst4/2411:00
B20Complete decomposition of 2-propanol using AOP techniques with an immobilized TiO2 nonwoven and O3 microbubbles4/2411:20
B21Evaluation of chemical reactivity of VOC gas with ultrasonic mist activated by AOP techniques4/2411:40
B22The determination method of nitrosoamine in the air using SPME |Thermal desorption method|4/2414:50
B23The measurement of SVOC concentration on the surface of PVC sheet by Wipping Method4/2415:10
B24SVOC adsorption mechanism on airborne particle surface in indoor air4/2415:30
B25Experimental study on reduction performance of interior finishings for chemical pollutants4/2415:50
B26Evaluation for outgassing contaminants in a vacuum condition 4/2416:10
B27Development of a rapid analytical method for PAHs with a curie point pyrolyzer4/2416:30
C01Influence on smoking booth layout for air quality in indoor environment4/2310:00
C02Enhancement of Indoor Ventilation Efficiency with Fluctuating Airflow4/2310:20
C03Study on layout planning of air inlet/outlet :Part 3 In case of complex shaped room4/2310:40
C04Examination of air-conditioning system contamination and proposal of assessment guideline (4)4/2311:00
C05Air quality in office building :Part 5 Actual survey applying Act on Maintenance of Sanitation in Building 4/2311:20
C06A study on the characteristics of general-purpose dust counters4/2311:40
C07A study on the indoor air pollutants emitted from unvented combustion appliances 4/2313:00
C08Space isolation of environmental tobacco smoke at a low interfacial air velocity in terms of its dynamic behaviors4/2313:20
C09Comparison of humidification efficiency between superheated steam and saturated steam4/2313:40
C10Electrostatic collection of ultrafine particles using ultrasonically atomized droplets4/2314:00
C11Structurization of Electrospun Nanofiber Layer for Aerosol Filtration4/2314:20
C12Dust loading characteristics of nanofiber-layered filters4/2314:40
C13The comparison of test powders (SAP3-3 vs. JIS-11) on performance test for general ventilation air filter4/2315:00
C14Scanning Leak Test based on ISO 29463-44/2315:20
C15Investigation of HEPA filter media for energy-saving4/2315:40

E-mailFjaca@jaca-1963.or.jp
Copyright(C)2001 Japan Air Cleaning Association