ฉๅ๏ฤเึ | vO๚{๊ล |
EEE ๆ30๑คๅ๏vO p๊ล EEE
30th Annual Technical Meeting on Air Cleaning and Contamination Control Program
No. | Title | Date | Time |
A01 | Characterization of release of nanomaterial-derived particles and their collection by inertial samplers | 4/23 | 10:00 |
A02 | Evaluation of gas adsorption artifacts in the collection of atmospheric ultrafine particles using inertial filter sampler | 4/23 | 10:20 |
A03 | Extending the size range for calibrating the counting efficiency of the light scattering airborne particle counters toward larger particle sizes | 4/23 | 10:40 |
A04 | Optical measurement method for particles on printed substrate surface by light-scattering | 4/23 | 11:00 |
A05 | Examination of measurement method for environmental Japanese cedar pollen allergen | 4/23 | 11:20 |
A06 | Stochastic detection method of contamination on real-time from time variation in aerosol number concentration | 4/23 | 11:40 |
A07 | Development of a Computational Software for the Annual Energy Consumption of High-Tech Fabs | 4/23 | 13:00 |
A08 | Experimental study on smart factory energy management system for cleanroom | 4/23 | 13:20 |
A09 | Measurement and Analysis of Heat Dissipation Characteristic of Manufacturing Equipment to Cleanroom | 4/23 | 13:40 |
A10 | Improving the Dehumidification Performance and Energy Efficiency of Low Dew Point Desiccant Dehumidifier | 4/23 | 14:00 |
A11 | Study on Preventive Measures against Exposure to Nanomaterials at Workplace | 4/23 | 14:20 |
A12 | Research on the gTask and Ambienth Air Cleaning System (Part.12 Reentrainment of deposited particles) | 4/23 | 14:40 |
A13 | Expected performances and effectiveness of Air Shower | 4/23 | 15:00 |
A14 | Airflow characteristic around door opening with moving objects | 4/23 | 15:20 |
A15 | Pre-particle Filtration and Moisture Control by efficient purging in various inlet and outlet of a 450 mm wafer Front-Opening Unified Pod | 4/24 | 9:40 |
A16 | Study on Assessing the Particulate Containment Performance in Facility for High Potent Pharmaceutical Compounds | 4/24 | 10:00 |
A17 | A study of an evaluation technique of the hazardous particulate containment performance in the facilities for highly active medicals (Part 3) | 4/24 | 10:20 |
A18 | Basic study of biological particle detection method utilizing auto fluorescence | 4/24 | 10:40 |
A19 | Research on the "Task and Ambient" BCR Operating Room | 4/24 | 11:00 |
A20 | Task Air Cleaning System for Hybrid Operating Room | 4/24 | 11:20 |
A21 | Verification of the effect of gpush-pullh airflow to reduce the concentration of airborne microbe generated by coughing equipment using BN-spores | 4/24 | 11:40 |
A22 | Sterilization with Ozone in a Clean Room of Pharmaceutical Manufacturing Facility | 4/24 | 14:50 |
A23 | Experimental Results of Bio-decontamination Technology for using Hydrogen Peroxide Vapor | 4/24 | 15:10 |
A24 | Effect of Additives on Sterilization of Bacteria by Atmospheric Microplasma | 4/24 | 15:30 |
B01 | On the actual condition to indoor air distribution and microbe concentration in a high airtight residence. (Part 3) | 4/23 | 10:00 |
B02 | Theoretical examination about the mold multiplication characteristic in the building-materials surface | 4/23 | 10:20 |
B03 | Characteristic of the fungus contamination in a heat cool trench | 4/23 | 10:40 |
B04 | Fundamental examination about the multiplication characteristic of the fungus in a coexistence state | 4/23 | 11:00 |
B05 | Onsite certification of HEPA filter mounted on class II biological safety cabinets: significant insensitivity of tests utilizing particle counters | 4/23 | 11:20 |
B06 | A recent experience with onsite certification of class II biological safety cabinet | 4/23 | 11:40 |
B07 | Investigation of radioactive particles in aerosol at Fukushima Prefecture | 4/23 | 13:00 |
B08 | A study on counter measure technique against environmental pollution caused by radioactive substances (Part 1), Development of recovery-circulation-type decontamination machine | 4/23 | 13:20 |
B09 | Cancelled | 4/23 | 13:40 |
B10 | A study on recovery method of the used activated carbon adapted for air clean device (Part 1) | 4/23 | 14:00 |
B11 | A study on the odor substance on the toilet deodorant devices | 4/23 | 14:20 |
B12 | Influence of removal performance by the particle removal test for portable air cleaner | 4/23 | 14:40 |
B13 | Countermeasure of Formaldehyde in the Hospital | 4/23 | 15:00 |
B14 | High performance filter utilizing nano-fiber non-woven sheets | 4/23 | 15:20 |
B15 | Development of removal technology for IPA (Isoropyl alcohol) in exhaust gas by spraying removal solution | 4/24 | 9:40 |
B16 | Development of the regeneration equipment for the waste solvent which absorbs VOC gas by vacuum evaporation with air flow | 4/24 | 10:00 |
B17 | Removal of volatile organic compounds by spraying APA (acrylamide polyampholyte)-containing solution using various sorts of spraying method | 4/24 | 10:20 |
B18 | A study on pollutant removal performance by photocatalyst products | 4/24 | 10:40 |
B19 | Evaluation of VOC decomposition ability by the difference of ozone decomposition catalyst | 4/24 | 11:00 |
B20 | Complete decomposition of 2-propanol using AOP techniques with an immobilized TiO2 nonwoven and O3 microbubbles | 4/24 | 11:20 |
B21 | Evaluation of chemical reactivity of VOC gas with ultrasonic mist activated by AOP techniques | 4/24 | 11:40 |
B22 | The determination method of nitrosoamine in the air using SPME |Thermal desorption method| | 4/24 | 14:50 |
B23 | The measurement of SVOC concentration on the surface of PVC sheet by Wipping Method | 4/24 | 15:10 |
B24 | SVOC adsorption mechanism on airborne particle surface in indoor air | 4/24 | 15:30 |
B25 | Experimental study on reduction performance of interior finishings for chemical pollutants | 4/24 | 15:50 |
B26 | Evaluation for outgassing contaminants in a vacuum condition | 4/24 | 16:10 |
B27 | Development of a rapid analytical method for PAHs with a curie point pyrolyzer | 4/24 | 16:30 |
C01 | Influence on smoking booth layout for air quality in indoor environment | 4/23 | 10:00 |
C02 | Enhancement of Indoor Ventilation Efficiency with Fluctuating Airflow | 4/23 | 10:20 |
C03 | Study on layout planning of air inlet/outlet :Part 3 In case of complex shaped room | 4/23 | 10:40 |
C04 | Examination of air-conditioning system contamination and proposal of assessment guideline (4) | 4/23 | 11:00 |
C05 | Air quality in office building :Part 5 Actual survey applying Act on Maintenance of Sanitation in Building | 4/23 | 11:20 |
C06 | A study on the characteristics of general-purpose dust counters | 4/23 | 11:40 |
C07 | A study on the indoor air pollutants emitted from unvented combustion appliances | 4/23 | 13:00 |
C08 | Space isolation of environmental tobacco smoke at a low interfacial air velocity in terms of its dynamic behaviors | 4/23 | 13:20 |
C09 | Comparison of humidification efficiency between superheated steam and saturated steam | 4/23 | 13:40 |
C10 | Electrostatic collection of ultrafine particles using ultrasonically atomized droplets | 4/23 | 14:00 |
C11 | Structurization of Electrospun Nanofiber Layer for Aerosol Filtration | 4/23 | 14:20 |
C12 | Dust loading characteristics of nanofiber-layered filters | 4/23 | 14:40 |
C13 | The comparison of test powders (SAP3-3 vs. JIS-11) on performance test for general ventilation air filter | 4/23 | 15:00 |
C14 | Scanning Leak Test based on ISO 29463-4 | 4/23 | 15:20 |
C15 | Investigation of HEPA filter media for energy-saving | 4/23 | 15:40 |
E-mailFjaca@jaca-1963.or.jp
Copyright(C)2001 Japan Air Cleaning Association